ESA KOREA

PORTFOLIO

Fixed test furnace F1 with combustion air heater

ESA Combustion Centre

Combustion Technology Portfolio

Patents

The furnace is used for long flame burners or for burners with roof top radiant tubes up to a maximum power of 2 MW fed by natural gas, LPG, other gases (COG, BFG) or diesel. It is provided with 2 cooled peepholes for inspection.

  • Size of combustion chamber: 6200 x 2200 x 1600 H.
  • N. 1 front slot for burner Ø 780 with air inlet DN350 (2 MW max).
  • N. 1 roof top slot for burner Ø 500 with air inlet DN100 (500 KW max)
  • N. 1 roof top slot for burner Ø 600 with air inlet DN150 (1000KW max).
  • Max combustion chamber temperature 1300 °C.
  • Maximum preheated air temperature 550 °C.
  • “Tubular bundle” heat exchanger and radiant tube exchanger.
  • Maximum air flow Qmax = 2500 Nm3/h @ 500 °C.
  • Fixed flue gas analyzer SIEMENS ULTRAMAT 23 (O2, CO and NO/NOx).
  • Measurement of the flow of air and gas through POP-U-S calibrated flanges (see data sheet E5719).
  • N° 6 “S” series thermocouples (4 on the side wall of the furnace and 2 on the roof).
  • Automatic control of the pressure in the combustion chamber.