F7 fixed test furnace 4MW

ESA Combustion Centre

Combustion Technology Portfolio

Patents

The furnace is used to test long flame burners, burners with roof radiant tubes, radiant burners with capacity up to 4 MW. It is fed by natural gas, LPG, various producers’ gases (COG, BFG…) or diesel. It is provided with 6 cooled peepholes for inspection.

  • Size of combustion chamber: 8000 x 2200 x 2000 H
  • N° 1 front slot for burner Ø 950 with air inlet DN400 (4 MW max).
  • N° 1 roof top slot for burner Ø 600 with air inlet DN200 (1000 KW max).
  • N° 2 front slots for regenerative burners Ø 950 with air inlet DN400 (4 MW max).
  • Maximum combustion chamber temperature: 1300 °C.
  • Maximum preheated air temperature: 600 °C. The preheated air temperature regulation is indipendent from furnace temperature
  • Tube bundle heat exchanger + additional heater.
  • N° 12 water cooling tubes with evaporation towers having a maximum absorption of 1200 KW.
  • Combustion air blower with maximum air flow Qmax = 4000 Nm3/h @ 500 °C.
  • Combustion flue extractor with maximum flow of Qmax = 4000 Nm3/h @ 250 °C (for regenerative burners).
  • Portable smoke analyzers TESTO 350XL for various gases (O2, CO and NO/NOx).
  • N° 6 thermocouples “S” series (4 on the furnace wall and 2 on the roof).
  • Measurement of the flow of air and gas through POP-US calibrated flanges (see data sheet E5719).
  • Supervisor camera.
  • Automatic control of the pressure in the combustion chamber (via chimney or extractor).
  • Mobile front panel installed on rails. Possibility of having various slots for burners by replacing into frontal furnace wall.